Camp Pendleton runs on federal fire rules. As a Department of Defense installation, the base follows UFC 3-600-01, the federal standard for fire protection engineering on military facilities, in place of a city or county fire code.

Inspections are a separate job. The Camp Pendleton Fire Department's Fire Prevention Branch, led by the base Fire Marshal, does fire inspections on the installation. If an inspector has written up your hood system, keep the report handy when you call us.

New building or major remodel? The same branch reviews plans and fire protection design for all new construction on base, so if your kitchen system is part of a construction project, confirm with the Fire Marshal's office what it needs before work starts.

What a hood suppression service covers

NFPA 96 and NFPA 17A call for a commercial cooking suppression system to be inspected every six months. On a typical visit, a technician checks that the nozzles are clean, capped and aimed at the appliances they protect, replaces the metal-alloy fusible links (NFPA 96 puts them on the same schedule), looks over the agent cylinder and pull station, and tests that the system shuts off fuel or power to the cooking line when it trips. Then the tag gets updated. Inspectors read that tag first.

Every kitchen with a hood system also needs a Class K portable extinguisher for cooking oils and fats. Wet chemical units like that get a hydrostatic test every five years, which we can handle through our hydrostatic testing service on Camp Pendleton. The extinguisher also needs annual maintenance and a tag, covered under fire extinguisher annual certification.

UL 300 fire kitchen system upgrades

UL 300 is the test standard for pre-engineered wet chemical systems that protect cooking appliances. Older dry chemical systems don't meet it. If your hood still has a dry chemical system, a technician can point that out during an inspection, and the usual path from there is replacing it with a UL 300 wet chemical system sized to the appliances on your line.

Changed your fryers or griddles? The nozzle layout may need to change too. We also remove systems when a kitchen closes or a hood comes out.

Getting on base and who does the work

Camp Pendleton is a closed installation. Off-base contractors need base access before they can do any on-site work, so plan the visit with your facility contact and give us the building number and the area it's in (Mainside, 21 Area Del Mar, 43 Area Las Pulgas, 62 Area San Mateo and so on).

California work for 1 Pro Fire is performed by Hedrick Fire Protection. Hedrick holds C-16 (fire protection) and C-10 (electrical) contractor licenses, is licensed by the California State Fire Marshal under Title 19 for extinguisher and water-based system service, and is licensed to install and service commercial kitchen hood fire suppression systems.

Call (619) 568-5440 or email socal@1profire.com to set up a visit.

More on base and nearby: the Camp Pendleton service area page, fire sprinkler service on Camp Pendleton, and kitchen suppression service in San Diego County, Orange County and Riverside County.

Kitchen suppression questions

Has this kitchen system been serviced before?

Check the service tag on the system. It shows the last service date and who did the work. No tag, or an old one? Book an inspection.

How often does a hood suppression system need service?

Every six months under NFPA 96 and NFPA 17A.

Can our existing dry chemical system stay in place?

It doesn't meet UL 300, the current test standard for wet chemical kitchen systems. Ask the base Fire Marshal's office whether your existing system has to be replaced on your timeline, and we can price a UL 300 wet chemical replacement for your hood.

Our services include

Fire Kitchen System Installation
Restaurant Hood Systems Service

Schedule hood suppression service on Camp Pendleton

(619) 568-5440 or socal@1profire.com

Have your inspection report or last service tag ready when you call.