Who needs extinguisher training in Saticoy
Start with one question: are your employees expected to use the extinguishers on the wall? If yes, federal rule 29 CFR 1910.157(g) applies. Staff must be trained when they're hired and at least once a year after that. The rule doesn't change with the address, so a crew in the industrial area on both sides of Los Angeles Avenue and a counter clerk in Old Town Saticoy are held to the same yearly schedule.
New hire? Train them. Same crew next year? Train them again.
What your people learn
A session is built around the extinguishers already in your building. Those are the ones your staff will reach for.
- The letters on the label. Class A is for ordinary combustibles, B for flammable liquids, C for energized electrical equipment, D for combustible metals and K for cooking oils and fats.
- How to discharge it. Pull the pin, aim at the base of the fire, squeeze the handle and sweep side to side.
- When to walk away. If the fire is growing past what one extinguisher can handle, or it sits between you and the exit, leave the building and call 911.
- The monthly look. The owner checks each unit every month: is the gauge in the green, are the pin and seal intact, is the tag current and is the path to it clear?
Training covers people. The tag covers the extinguisher.
Training doesn't renew an extinguisher's service. Each unit still needs annual maintenance by a certified technician, recorded on a tag. Some need more: stored-pressure dry chemical units get a 6-year internal teardown, and hydrostatic testing comes every 12 years for dry chemical and every 5 years for CO2, water and wet chemical (Class K) units. See annual extinguisher certification in Saticoy and extinguisher hydrostatic testing in Saticoy for how those visits go.
Who may do that work? In California, extinguisher service must be done by a firm and technician licensed by the State Fire Marshal under Title 19. Our California work is performed by Hedrick Fire Protection, which holds C-16 (fire protection) and C-10 (electrical) contractor licenses and is State Fire Marshal licensed under Title 19 for portable extinguisher service. Units that are low or partly used need a fire extinguisher refill.
Old Town or annexed Saticoy: know your fire code
Saticoy is split. Old Town Saticoy is still unincorporated, and there the Ventura County Fire Department Fire Prevention Bureau inspects businesses for compliance with the county fire code. Most of Saticoy outside Old Town is now part of the City of Ventura. Those parcels follow the city's fire code ordinance, and City of Ventura Fire Department inspectors check new and existing buildings.
Statewide, extinguisher rules live in California Fire Code Section 906. The county code now in effect is based on the 2022 edition, and a newer county code has been drafted, so confirm the current edition with the inspector for your parcel.
Book a session
To set up fire extinguisher training for your Saticoy staff, call (213) 568-0188 or email socal@1profire.com. Tell us how many people need it and which extinguishers you have.
Saticoy extinguisher training questions
How often do employees need fire extinguisher training?
Where an employer provides portable extinguishers for staff to use, OSHA rule 29 CFR 1910.157(g) calls for training at hire and at least once a year after that.
Does training replace the annual extinguisher service?
No. Training is for your people. Each extinguisher still needs annual maintenance by a State Fire Marshal licensed technician, recorded on its tag.
Which fire department covers my business in Saticoy?
It depends on the parcel. Old Town Saticoy is unincorporated and falls under the Ventura County Fire Department's Fire Prevention Bureau, while most of the rest of Saticoy is in the City of Ventura, where city fire inspectors cover buildings.
Do kitchen staff need to know about Class K?
Yes. A kitchen with a hood suppression system also needs a Class K portable extinguisher for cooking oils and fats, and the cooks should know where it hangs and when to use it.
Questions before you book?
Ask us. We'll go over which extinguishers your crew should know.