Kitchens wear out sprinkler heads
A restaurant is a rough place for a sprinkler head. Cooking vapor drifts up from the line and leaves a film of grease on every head nearby, while steam from the dish area and strong cleaning chemicals can corrode the frame and the heat-sensitive element over time. Then there are ladders, tall racks and delivery carts.
Some problems show up on an inspection report. Others show up as a drip.
These are the repairs restaurants call about most often in the trade:
- Heads coated with grease, paint or overspray, often after a remodel or a deep clean of the kitchen
- A head that was bent or knocked loose by a ladder, a rack or a cart
- Drips or leaks at a head or a pipe fitting
- Ceiling work that left a head missing its cover plate, set at the wrong depth or blocked by new shelving
- Gauges, valves or other items written up as deficiencies on an inspection
A head that is loaded with grease, painted, corroded or damaged can't be trusted to open when it should. Under NFPA 25, it gets replaced.
How a repair visit goes
The technician first finds the cause. A leak at a fitting is a different job from a head that a cart hit, and a grease problem near the hood usually means checking every head in that area, not only the one someone noticed.
Replacement heads must match what's there. That means the same temperature rating, response type and coverage, so the new head behaves the way the system was designed. Next the technician closes the right control valve and drains that section. After the part is changed, the system is refilled, checked for leaks and returned to service with its valves open.
Downtime is usually short. Ask your fire authority whether it wants notice before the system goes out of service.
Old buildings need one more check. NFPA 25 requires sprinkler heads that have been in service 50 years to be replaced or sample-tested, so if your heads are original to an older building, it's worth finding out when they went in.
Which fire office covers your address in Saticoy
Saticoy is split between two jurisdictions. Which one applies depends on where your restaurant sits.
- Old Town Saticoy (unincorporated): the Ventura County Fire Department Fire Prevention Bureau inspects businesses for fire code compliance and reviews plans for remodels.
- The rest of Saticoy (annexed into the City of Ventura): the City of Ventura fire code ordinance applies, and City of Ventura Fire Department inspectors inspect existing buildings and occupancies.
If an inspector wrote up a sprinkler deficiency, keep a record of the repair for that office. If you're planning a kitchen remodel that moves heads or adds them, check plan review requirements with the same office first.
Who does the work
Our California work is performed by Hedrick Fire Protection. Hedrick holds C-16 (fire protection) and C-10 (electrical) contractor licenses and is licensed by the California State Fire Marshal under Title 19 for inspection, testing and maintenance of water-based fire protection systems like your sprinklers. Hedrick is also licensed to install and service commercial kitchen hood fire suppression systems, so the system over your cook line can be handled too; see our kitchen hood suppression service in Saticoy.
Saticoy is in our service area. To set up a repair, call us at (213) 568-0188 or email socal@1profire.com. Tell us what you're seeing and the address.
Restaurant sprinkler repair questions
Can I wipe the grease off a sprinkler head myself?
No. A grease-loaded head is replaced under NFPA 25. Cleaning can damage the element and change how the head responds in a fire.
Will my sprinklers be off during the repair?
Usually only the affected section, and only while it is drained, fixed and refilled. Ask your fire authority if it wants notice.
Is my restaurant under the county or the City of Ventura?
Old Town Saticoy is unincorporated and falls under the Ventura County Fire Department. Most of Saticoy outside Old Town has been annexed into the City of Ventura, where the city fire department inspects. Not sure? Ask the office that last inspected you.
Is the hood system part of this repair?
No. It's a separate system. Hedrick is licensed to install and service hood suppression systems, so we can look at both on one call if you ask.
Related links
- Fire protection services in Saticoy
- Restaurant sprinkler inspections in Saticoy
- Fire sprinkler service in Saticoy
- Fire extinguisher service in Saticoy
- Restaurant sprinkler repair in Los Angeles County
- Restaurant sprinkler repair in Orange County
- Ventura County Fire Department Fire Prevention Bureau
Sprinkler problem in your kitchen?
Old Town or the City of Ventura side, send us the address and what you're seeing.
(213) 568-0188