Who has to train, and how often
When a Hawthorne employer puts portable extinguishers on the wall for employees to use, federal OSHA rule 29 CFR 1910.157(g) requires training at initial employment and at least once a year after that. Keep a sign-in sheet for each session so you can show who was trained and when, and see who is due next year.
What staff learn in a session
Staff learn to match the extinguisher to the fire.
- Class A: ordinary combustibles such as wood, paper and cloth.
- Class B: flammable liquids.
- Class C: energized electrical equipment.
- Class D: combustible metals.
- Class K: cooking oils and fats.
Kitchens protected by a hood suppression system also need a Class K portable unit, so anyone working the line should know which one it is and where it hangs before a grease fire starts. Water on a grease fire spreads it. The session also covers when a fire is too big to fight, and when staff should leave and call 911.
Licensed extinguisher service in Hawthorne
Training covers your people, and the yearly maintenance tag covers the equipment. California requires that extinguisher service be done by a firm and technician licensed by the State Fire Marshal under Title 19. Hedrick Fire Protection does our California work. It holds a C-16 fire protection contractor license and State Fire Marshal licensing under Title 19 for portable extinguisher service.
For the equipment side, see annual extinguisher certification in Hawthorne, extinguisher recharge after use and hydrostatic testing.
Fire code questions in Hawthorne
Hawthorne has no city fire department. It contracts with the Los Angeles County Fire Department, and the department's Fire Prevention Division handles fire prevention work for the city from its Central Regional Office at 4475 W. El Segundo Blvd. in Hawthorne, (310) 263-2732. Ask that office what California Fire Code Section 906 requires for your building, such as which extinguisher types you need and where they go.
More training and Hawthorne pages
See all our fire protection services in Hawthorne, or compare extinguisher training across Los Angeles County and extinguisher training in Orange County.
To schedule training, call us at (213) 568-0188 or email us at socal@1profire.com
Related Links
Common questions
Can an extinguisher be refilled after it's used?
Yes, if it's a rechargeable unit. A licensed technician should recharge it after any discharge, even a short burst, while disposable units are replaced.
How long before a dry chemical extinguisher needs major service?
Six years. A stored-pressure dry chemical unit gets an internal teardown at 6 years and a hydrostatic test at 12 years, while CO2, water and wet chemical units are hydro tested every 5 years.
Who checks extinguishers between annual visits?
The owner, once a month. Trained staff can do the visual check: unit in place, gauge in the green, pin and seal intact, tag current.