Most sprinkler repairs start with a piece of paper. An inspection report, a correction notice from the fire marshal or an insurance survey lists what failed. Send it to us. Each line on that list points to a part we can find and replace, so a scan or a phone photo of the report usually lets us scope the job before anyone climbs a ladder.

No report yet? Describe what you see. A drip, a stained ceiling tile or a head knocked crooked by a delivery cart is enough to start.

What fails in a restaurant system

Kitchens are hard on sprinklers. Each problem below needs repair because it can stop a head from opening correctly or keep water from reaching the fire:

  • Heads coated with grease or paint. Coating can delay the release or block it.
  • Corroded or leaking heads. Steam and cleaning chemicals wear on the metal.
  • Heads with a cracked glass bulb or a bent frame.
  • Heads blocked by new shelving, signage or a hood change, which leaves part of the floor below outside the spray pattern.
  • Missing escutcheons or open ceiling gaps around a head, which let heat escape past it.
  • Leaking or stuck control valves, and gauges that read wrong or are past their replacement date.

Heads in service for 50 years must be replaced or sample-tested under NFPA 25. In an older building, that can mean a whole group of heads comes due at the same time, so it's worth checking the year stamped on your heads before the next inspection does it for you.

How a repair visit goes

First we find the control valve and confirm which part of the building it feeds. Then the water goes off. Before that happens, the owner should tell the alarm monitoring company and the fire department that the system will be out of service and for roughly how long. Fire protection in City Of Industry comes from the Los Angeles County Fire Department under contract with the city, with Station 118 on Gale Avenue and Station 61 in Walnut among the stations that serve it.

We drain the section, replace the failed parts, refill and look for leaks. Replacement heads must match. Type, temperature rating, orifice size and response speed all have to agree with the heads around them, because a mismatched head gets written up as a deficiency of its own. Last, we open the valve and confirm the alarm signals reset. Then we tell you the system is back in service.

Permits, licensing and what comes next

Swapping a head for a matching one is often treated differently from moving pipe or adding heads. Those may need plans and a permit. Confirm with the local fire marshal before work goes beyond replacement parts.

Our California work is performed by Hedrick Fire Protection. Hedrick holds C-16 (fire protection) and C-10 (electrical) contractor licenses and is licensed by the California State Fire Marshal under Title 19 to inspect, test and maintain water-based fire protection systems. Hedrick is also licensed to install and service commercial kitchen hood suppression systems (see kitchen fire suppression service in City Of Industry).

A repair closes out a deficiency. It doesn't reset the schedule. Your system still needs quarterly and annual inspections under NFPA 25 and the Title 19 five-year service and certification, which we cover under restaurant sprinkler inspections and fire sprinkler service.

Getting a quote in City Of Industry

We work across City Of Industry, including street addresses in ZIP codes 90601, 91732, 91744, 91745, 91746, 91748 and 91789. Other services for the city are on our City Of Industry fire protection page. Outside the city? See restaurant sprinkler repair in Los Angeles County or restaurant sprinkler repair in Orange County.

Send the report or a few photos. Call (213) 568-0188 or email socal@1profire.com

Our services include

Fire Kitchen System Installation
Restaurant Hood Systems Service
City Of Industry Links

Restaurant sprinkler repair questions

Does a damaged sprinkler head get repaired or replaced?

Damaged heads are replaced. Sprinkler heads aren't cleaned or repaired in place, so a painted, greasy, corroded or bent head comes out and a matching one goes in.

Will my kitchen have to close during the repair?

Usually not. Only the drained section loses protection, and many head swaps are short jobs. Ask the fire authority whether a fire watch is required while it's off.

Is the hood suppression system part of a sprinkler repair?

No. The hood system is a separate wet chemical system, and it has its own semi-annual inspection under NFPA 96 and NFPA 17A.