Skip to main content

Three schedules on one sprinkler system

A sprinkler system can sit idle for years. Then it has seconds to work. NFPA 25 is the standard that keeps it ready, and it splits the inspection, testing and maintenance work into three intervals that overlap on the same system: quarterly, annual and five-year.

  • Quarterly: a walk-through inspection of valves, alarm devices and gauges.
  • Annual: a fuller inspection and test of the system.
  • Every five years: an internal pipe assessment and gauge replacement or testing. In California, Title 19 also requires a five-year service and certification by a contractor licensed by the State Fire Marshal.

The five-year visit is the one people forget. Don't let it lapse. Sprinkler heads have a longer limit: once a head has been in service 50 years, NFPA 25 calls for replacing it or sending samples out for testing, so it helps to know roughly when your building's system went in.

What the technician checks

Most of a visit is looking and testing. The technician usually starts at the riser and works outward, checking that control valves are open and secured, gauges read normal pressure, the waterflow alarm sounds when water moves, and heads are free of paint, corrosion, damage or storage stacked too close below them. Is the fire department connection clear and capped? That gets checked too. Dry systems also get checks on the dry pipe valve and its air supply.

A failed item is a deficiency. It stays open until it's repaired and retested. If your waterflow switch reports to a fire alarm panel, that panel has its own annual test under NFPA 72, covered on our Camarillo fire alarm service page.

Who inspects in Camarillo, and who does the work

Camarillo falls under the Ventura County Fire Department. Its Fire Prevention Bureau handles plan review and fire code inspections for the city. If you're unsure what your building owes, call the Bureau at (805) 389-9744 or email fire.inspections@ventura.org, and ask which edition of the county fire code applies to your building.

Our California work is done by Hedrick Fire Protection. Hedrick holds C-16 (fire protection) and C-10 (electrical) contractor licenses and is licensed by the California State Fire Marshal under Title 19 for inspection, testing and maintenance of water-based fire protection systems, which includes the five-year certification.

Related work at the same building

Most of the calls we've had from Camarillo so far are about fire extinguishers. That's a separate service. If your site has both, see fire extinguisher service in Camarillo. Adding sprinklers or extending a system is covered under Camarillo fire sprinkler installation, and private hydrants on the same fire main are on our annual fire hydrant testing page for Camarillo. Everything else we do in the city is on the Camarillo fire protection hub.

Managing more than one site? See sprinkler service for Ventura County, Los Angeles County and Orange County.

Camarillo sprinkler service questions

How often does a sprinkler system in Camarillo need service?

Quarterly and annually under NFPA 25. Every five years, California's Title 19 adds a service and certification by a State Fire Marshal licensed contractor.

Who does fire code inspections in Camarillo?

The Ventura County Fire Department's Fire Prevention Bureau. Call (805) 389-9744 to confirm what your building needs.

Our property requires a vendor certificate of insurance. Can that delay service?

It can. Some sites won't release a work order until the contractor's certificate on file is current, so check yours before the scheduled date.

Our sprinkler heads are old. Do they need replacing?

Heads in service 50 years must be replaced or sample-tested under NFPA 25. Not sure of the age? Most heads carry a stamped year of manufacture.

To schedule sprinkler service in Camarillo, call (213) 568-0188 or email socal@1profire.com.

Book a sprinkler inspection in Camarillo

(213) 568-0188 or socal@1profire.com

Is your five-year due?

(213) 568-0188